Computed Tomographic Angiography in the diagnosis of brain death

Marcin Sawicki, Anna Walecka, Romuald Bohatyrewicz, Wojciech Poncyljusz, Janusz Kordowski

Med Sci Monit 2010; 16(1): 28-32 :: ID: 880579

Abstract

Two neurophysiological methods can demonstrate the cessation of brain function: electroencephalography (EEG) and brain-stem auditory-evoked potentials. Conventional angiography of the 4 cerebral arterial axes are the reference standard for imaging brain death. Thus, it is an invasive examination that needs an experienced neuroradiologist, and the availability of an angiography suite. The use of a computed tomographic (CT) scan to diagnose brain death (BD) was proposed in 1978. This examination developed widely these last years thanks to a new generation of multirow CT, which allows visualization of opacified cerebral vessels. This study sought to determine the accuracy of CT, for confirmation of BD.
We examined 15 patients with suspicion of BD according to clinical criteria defined by law. CT scan was performed with and without injection of contrast material, followed by cerebral angiography. In our material, CT angiography showed opacification of A2-ACA and M2 or M3-MCA in 10 patients. In our patients, results of CT angiography fulfill the criteria proposed by the French Society of Neuroradiology: absence of perfusion of M4 middle cerebral artery segments (M4-MCA) and deep cerebral veins. In conventional angiography, 2 patients showed, at the level of the anterior and middle cerebral artery, a phenomenon already described as stasis filling.
CT angiography is a promising radiologic examination in diagnosing BD. When confirmatory examinations are required among BD patients for whom the clinical diagnosis remains essential, it may be an interesting alternative to conventional cerebral angiography, which is more invasive and constraining, and when EEG is unavailable or inadequate.

Keywords: Brain Death, conventional angiography, CT, Angiography

Add Comment 0 Comments

Editorial

01 January 2025 : Editorial  

Editorial: The Human Cell Atlas. What Is It and Where Could It Take Us?

Dinah V. Parums

DOI: 10.12659/MSM.947707

Med Sci Monit 2025; 31:e947707

0:00

In Press

Clinical Research  

Impact of Periodontal Treatment on Early Rheumatoid Arthritis and the Role of Porphyromonas gingivalis Anti...

Med Sci Monit In Press; DOI: 10.12659/MSM.947146  

0:00

Clinical Research  

C-Reactive Protein, Uric Acid, and Coronary Artery Ectasia in Patients with Coronary Artery Disease

Med Sci Monit In Press; DOI: 10.12659/MSM.947158  

Clinical Research  

Effects of Remote Exercise on Physical Function in Pre-Frail Older Adults: A Randomized Controlled Trial

Med Sci Monit In Press; DOI: 10.12659/MSM.947105  

Database Analysis  

Development and Validation of a Competitive Risk Model in Elderly Patients with Transitional Cell Bladder C...

Med Sci Monit In Press; DOI: 10.12659/MSM.946332  

Most Viewed Current Articles

17 Jan 2024 : Review article   6,964,204

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

16 May 2023 : Clinical Research   700,526

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

01 Mar 2024 : Editorial   24,009

Editorial: First Regulatory Approvals for CRISPR-Cas9 Therapeutic Gene Editing for Sickle Cell Disease and ...

DOI :10.12659/MSM.944204

Med Sci Monit 2024; 30:e944204

0:00

28 Jan 2024 : Review article   18,806

A Review of IgA Vasculitis (Henoch-Schönlein Purpura) Past, Present, and Future

DOI :10.12659/MSM.943912

Med Sci Monit 2024; 30:e943912

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750